temperature sensor ntc thermistor cwf series have stability product performance,can work in long time with high reliability,they can be widely applied in temperature control of welding machines .
performance parameters:
model no.: cwf-103f3950fa
r25 = 10kω ± 1 %,
b25/50 = 3950k ± 1 %.
lead wire: ul2651 2c insulated and pair together 30awg 105℃ 300v ts black;
lead length: 100mm, 160mm, 230mm are normally.can also be customized according to the length required by the customer.
brief introduction:
temperature sensor ntc thermistor cwf series have stability product performance,annual resistance drift rate ≤5‰, can work in long time with high reliability,they can be widely applied in temperature control of welding machines .
product application:
applied in temperature control and heat protection of welding machine.
advantages of temperature sensor ntc thermistor:
1. high precise resistance and b value,good consistancey,interchangeable
(resistance and b value tolerance can be ±1%)
2. high sensitivity,fast response,temperature resistance coefficient can be (2~5)%/℃
3. high precise temperature control,
4. can be encapsulated based on specific installation condition,convenient for users' installation
5. good insulation,anti bending and anti mechanical collision,high reliability
dimension(unit: mm):

characteristic:
1.product name: ntc temperature sensor
2.r25 resistance:r25=10kω±1%,
3.b value: b25/50=3950k±1%
4.thermal response time:t1=25 (85-25)*63.2%=62.9℃ 8s max.in a water bath
5.dissipation coefficient:ta=25±0.5℃ around 2.5mw/℃.in the still air
6.hi-pot test:ac 1500v 2ma 6 6s,no flashover ,no breakdown in steel ball
7.insulation test:dc 500v 100mω,≥100mωin a steel ball
8.erp:mf52c103f3950l27026awg-nts0822
9.operating temperature:-30℃~105℃
reliability test:
1. high temperature experiment: 1000 hrs in air 100 ± 5 °c
2. low temperature experiment: -30 ± 5 °c 1000 hrs in air
3. temperature cycle experiment: -30 °c / 30 minutes. room temperature 10 minutes. 100 °c / 30 minutes 10 cycles
4. electricity experiment: dco 0.2 ma 1000 hrs in constant temperature and humidity
5. lead strength: the force applied to 20n lasts 1 minute
6. fall experiment: free fall of mud floor from 1m height
after the above performance test, there is no change in voltage resistance, insulation performance, and appearance without damage.
storage method:
1. no more than 4 boxes of products per stack height during storage and transportation;
2. dry agent should be placed in the bag. avoid direct or indirect showers and mechanical damage from rain and snow;
3. products should be stored at room temperature and often wet, and the surrounding environment should not be acidic,
alkaline substances and corrosive gases or radiation sources.